Assay Chip - Barrier and blister integration - Fluidic 1530
search
  • Assay Chip - Barrier and blister integration - Fluidic 1530
  • Assay Chip - Barrier and blister integration - Fluidic 1530
  • Assay Chip - Barrier and blister integration - Fluidic 1530
  • Assay Chip - Barrier and blister integration - Fluidic 1530

Description

The assay chip Fluidic 1530 is designed to introduce agarose beads into a trapping chamber, holding back the beads (but allowing smaller particles to pass). Coated agarose beads allow annealing of different cells or small molecules and thereby can be used for isolation and purification tasks in various molecular biologic applications. The chip features further in- and outlets, a large analysis chamber for optical read-out as well as two seats for blister integration, allowing for storage of reagents needed for on-chip analysis.

Fluidic 1530 features Luer interfaces allowing the direct use of Luer syringes to fill the chamber with agarose beads (not included).

This chip is not delivered with blisters. Blisters with custom filling can be ordered from microfluidic ChipShop - please contact us through Inquiries@microfluidic-ChipShop.com!

Assay Chip Barrier and blister integration Fluidic 1530

The assay chip Fluidic 1530 features a trapping chamber for agarose beads integration to isolate small molecules or cells.

€52.75 / unit
€43.00 / unit from 10 units
€32.60 / unit from 100 units
favorite_border favorite
Reference
10002067
Design element
Blister
Application
Sorting
Usage Statement
For R&D use only, Single use
Fluidic
1530
Material
Topas
Material chip body
Mcs-COC 13
Material chip lid
Mcs-foil 011 (Topas, 140 µm, Tg 78°C)
Color
Transparent
Interface type
Luer
Surface treatment
Not treated
Membrane
Mcs-membrane 058 (0.45 µm pore size, PTFE)
Pieces per unit
1

Description

The assay chip Fluidic 1530 is designed to introduce agarose beads into a trapping chamber, holding back the beads (but allowing smaller particles to pass). Coated agarose beads allow annealing of different cells or small molecules and thereby can be used for isolation and purification tasks in various molecular biologic applications. The chip features further in- and outlets, a large analysis chamber for optical read-out as well as two seats for blister integration, allowing for storage of reagents needed for on-chip analysis.

Fluidic 1530 features Luer interfaces allowing the direct use of Luer syringes to fill the chamber with agarose beads (not included).

This chip is not delivered with blisters. Blisters with custom filling can be ordered from microfluidic ChipShop - please contact us through Inquiries@microfluidic-ChipShop.com!