Description

Droplet generator chips with a double cross geometry allow for the generation of W/W/O droplets and are therefore ideally suited for the inclusion of particles or cells, deriving from the first channel intersection, with a further droplet shell at the second channel intersection.

With 38 μm nozzle diameter, Fluidic 536 offers the smallest nozzle size with double cross geometry within microfluidic ChipShop‘s portfolio. Please be aware of the chip‘s Luer interfaces, which require dedicated Luer-sized connectors and plugs. Operation of one unit of Fluidic 536 requires a microfluidic pump with the ability to control three individual flows, one for the continuous and one for the disperse phase.

To learn more about droplet generation check the droplet generation booklet in the attachments or watch the video below.

Droplet Generator with Double Cross 38 µm nozzles Fluidic 536

Droplet generator chips Fluidic 536 provides three identical droplet generator units with a nozzle size of 38 μm on one chip.

Material
€42.20 / unit
€34.40 / unit from 10 units
€26.10 / unit from 100 units
favorite_border favorite
Reference
10000433
Application
Droplet generation
Usage Statement
For R&D use only, Single use
Fluidic
536
Material
Topas
Material chip body
Mcs-COC 13
Material chip lid
Mcs-foil 011 (Topas, 140 µm, Tg 78°C)
Color
Transparent
Interface type
Luer
Surface treatment
Not treated
Membrane
No membrane
Pieces per unit
1

Description

Droplet generator chips with a double cross geometry allow for the generation of W/W/O droplets and are therefore ideally suited for the inclusion of particles or cells, deriving from the first channel intersection, with a further droplet shell at the second channel intersection.

With 38 μm nozzle diameter, Fluidic 536 offers the smallest nozzle size with double cross geometry within microfluidic ChipShop‘s portfolio. Please be aware of the chip‘s Luer interfaces, which require dedicated Luer-sized connectors and plugs. Operation of one unit of Fluidic 536 requires a microfluidic pump with the ability to control three individual flows, one for the continuous and one for the disperse phase.