Channel array chip - Various channel depths - Fluidic 1340
search
  • Channel array chip - Various channel depths - Fluidic 1340
  • Channel array chip - Various channel depths - Fluidic 1340
  • Channel array chip - Various channel depths - Fluidic 1340
  • Channel array chip - Various channel depths - Fluidic 1340
  • Channel array chip - Various channel depths - Fluidic 1340

Description

This straight channel chip features 16 channels with same dimensions besides the cavity depth. The varying channel depth and the resulting different channel volumes allow for direct comparison of the channel depth influence on an assay or measurement. These chips are the perfect tools to help choosing the right channel dimensions in the design process of integrated microfluidic devices.

Fluidic 1340 features eight pairs of channels, which share the same channel dimensions and are located next to each other. The channel depth increases in 10-20 µm steps:

  1. Two channels with 10 µm depth
  2. Two channels with 20 µm depth
  3. Two channels with 30 µm depth
  4. Two channels with 40 µm depth
  5. Two channels with 50 µm depth
  6. Two channels with 60 µm depth
  7. Two channels with 80 µm depth
  8. Two channels with 100 µm depth

Channel array chip Various channel depths Fluidic 1340

This straight channel chip features 16 channels with various channel depths, enabling direct comparison of this parameter on your assay or measurement.

Material
Surface Treatment
€42.20 / unit
€34.40 / unit from 10 units
€26.10 / unit from 100 units
favorite_border favorite
Reference
10002056
Design element
Channel
Usage Statement
For R&D use only, Single use
Fluidic
1340
Material
Topas
Material chip body
Mcs-COC 13
Material chip lid
Mcs-foil 011 (Topas, 140 µm, Tg 78°C)
Color
Transparent
Interface type
Mini luer
Surface treatment
Not treated
Membrane
No membrane
Pieces per unit
1

Description

This straight channel chip features 16 channels with same dimensions besides the cavity depth. The varying channel depth and the resulting different channel volumes allow for direct comparison of the channel depth influence on an assay or measurement. These chips are the perfect tools to help choosing the right channel dimensions in the design process of integrated microfluidic devices.

Fluidic 1340 features eight pairs of channels, which share the same channel dimensions and are located next to each other. The channel depth increases in 10-20 µm steps:

  1. Two channels with 10 µm depth
  2. Two channels with 20 µm depth
  3. Two channels with 30 µm depth
  4. Two channels with 40 µm depth
  5. Two channels with 50 µm depth
  6. Two channels with 60 µm depth
  7. Two channels with 80 µm depth
  8. Two channels with 100 µm depth

You might also like