Reaction Chamber Chip - 20 µl chamber volume - Fluidic 584
search
  • Reaction Chamber Chip - 20 µl chamber volume - Fluidic 584
  • Reaction Chamber Chip - 20 µl chamber volume - Fluidic 584
  • Reaction Chamber Chip - 20 µl chamber volume - Fluidic 584
  • Reaction Chamber Chip - 20 µl chamber volume - Fluidic 584

Description

Reaction chamber chips belong to the simplest, however most versatile, microfluidic devices. From basic reaction chamber to cell culture tool - many experimental setups can be facilitated with this chip. Fluidic 584 is particularly suited to be used for heat-cycle applications, such as PCR experiments, during which small air bubbles can form within the chambers of a microfluidic chip. For undisturbed fluorescent readouts, this microfluidic chip features microfluidic ChipShop‘s unique bubble-trapping-rim-design, specifically developed to keep the detection area of each chamber air bubble-free.

Please make sure to select the right material and surface treatment for your particular experiment. For instance, for PCR applications with fluorescent readouts we recommend the use of Zeonor or PCR-suitable Topas, for cell culture experiments with adherend cells, we recommend the use of hydrophilized surfaces, which aid cell attachment.

Reaction Chamber Chip 20 µl chamber volume Fluidic 584

This reaction chamber chip with a chamber volume of 20 µl and a chamber depth of 500 µm is a versatile microfluidic tool.

Material
Surface Treatment
€36.20 / unit
€24.30 / unit from 10 units
€16.10 / unit from 100 units
favorite_border favorite
Reference
10001294
Design element
Chamber
Application
PCR, Cell culture
Usage Statement
For R&D use only, Single use
Fluidic
584
Material
Topas
Material chip body
Mcs-COC 13
Material chip lid
Mcs-foil 011 (Topas, 140 µm, Tg 78°C)
Color
Transparent
Interface type
Mini Luer interface
Surface treatment
Not treated
Membrane
No membrane
Pieces per unit
1

Description

Reaction chamber chips belong to the simplest, however most versatile, microfluidic devices. From basic reaction chamber to cell culture tool - many experimental setups can be facilitated with this chip. Fluidic 584 is particularly suited to be used for heat-cycle applications, such as PCR experiments, during which small air bubbles can form within the chambers of a microfluidic chip. For undisturbed fluorescent readouts, this microfluidic chip features microfluidic ChipShop‘s unique bubble-trapping-rim-design, specifically developed to keep the detection area of each chamber air bubble-free.

Please make sure to select the right material and surface treatment for your particular experiment. For instance, for PCR applications with fluorescent readouts we recommend the use of Zeonor or PCR-suitable Topas, for cell culture experiments with adherend cells, we recommend the use of hydrophilized surfaces, which aid cell attachment.