Multi-Cavity Cross-Flow Membrane Chip - Four chambers with in-line sensing - Fluidic 1356
search
  • Multi-Cavity Cross-Flow Membrane Chip - Four chambers with in-line sensing - Fluidic 1356
  • Multi-Cavity Cross-Flow Membrane Chip - Four chambers with in-line sensing - Fluidic 1356

Description

The micro-iPS profiler chip is a multi-organ platform featuring in total four interconnected cross-flow membrane chambers, to establish complex organoid models. Coming in standardized titer plate (Fluidic 923) or double slide format (Fluidic 1356) it ensures the compatibility with common laboratory equipment. The largest chamber is used for the preparation of a liver culture, whilst the other three chamber are used to display different types of kidney cell types.The main microfluidic circuit in the upper part connects all four chambers, for continuous perfusion. A second circuit in the lower part is used for the liver chamber solely and a third in the lower part of the three kidney chambers.The renal chambers are used for automatic media exchange (usually every 24 hours). Each chamber has individual inlet and outlet ports for cell seeding.

Fluidic 1356 features additional detection chambers and ports, compatible with the PreSens sensor system, allowing for continuous monitoring of pH, carbon dioxide and oxygen in the fluidic circuits. The ready-to-use SensorPlug consists of a Mini Luer interface, an optical fiber for read-out and a specific sensor at the tip of the fiber. The SensorPlug is mounted directly onto the microfluidic channel network, ensuring that the sensor gets into contact with the fluid pathway. Thereby, changes in the concentration can be monitored in real-time. 

The chips are only recommended for low-pressure applications, in order to avoid leakage at the sensor ports. If you don’t need the sensor ports we recommend to close them with our Mini Luer plugs or Mini Luer caps (10001687) in TPE.

Multi-Cavity Cross-Flow Membrane Chip Four chambers with in-line sensing Fluidic 1356

The multi-cavity cross-flow membrane chip Fluidic 1356 serves as a multi-organ platform with four interconnected cross-flow membrane chambers and the option of in-line sensor integration.

Surface Treatment
€135.98 / unit
€90.50 / unit from 10 units
€66.40 / unit from 100 units
favorite_border favorite
Reference
10002053
Design element
Membrane
Application
Cell culture
Usage Statement
For R&D use only, Single use
Fluidic
1356
Material
Zeonor
Material chip body
Mcs-COP 02
Material chip lid
Mcs-foil 005 (Zeonor, 188 µm, Tg 136°C)
Color
Transparent
Interface type
Mini luer
Surface treatment
Hydrophilized
Membrane
Mcs-membrane 120 (8 µm pores, PET, transparent)
Pieces per unit
1

Description

The micro-iPS profiler chip is a multi-organ platform featuring in total four interconnected cross-flow membrane chambers, to establish complex organoid models. Coming in standardized titer plate (Fluidic 923) or double slide format (Fluidic 1356) it ensures the compatibility with common laboratory equipment. The largest chamber is used for the preparation of a liver culture, whilst the other three chamber are used to display different types of kidney cell types.The main microfluidic circuit in the upper part connects all four chambers, for continuous perfusion. A second circuit in the lower part is used for the liver chamber solely and a third in the lower part of the three kidney chambers.The renal chambers are used for automatic media exchange (usually every 24 hours). Each chamber has individual inlet and outlet ports for cell seeding.

Fluidic 1356 features additional detection chambers and ports, compatible with the PreSens sensor system, allowing for continuous monitoring of pH, carbon dioxide and oxygen in the fluidic circuits. The ready-to-use SensorPlug consists of a Mini Luer interface, an optical fiber for read-out and a specific sensor at the tip of the fiber. The SensorPlug is mounted directly onto the microfluidic channel network, ensuring that the sensor gets into contact with the fluid pathway. Thereby, changes in the concentration can be monitored in real-time. 

The chips are only recommended for low-pressure applications, in order to avoid leakage at the sensor ports. If you don’t need the sensor ports we recommend to close them with our Mini Luer plugs or Mini Luer caps (10001687) in TPE.