Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
search
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653
  • Cross-Flow Membrane Chip - Organ-on-Chip and more - Fluidic 653

Description

The cross-flow membrane chip Fluidic 653 possesses two independent chambers that interact through a permeable membrane. Each chamber features one main inlet and outlet, along with two additional (optional) inlets and outlets for additional reagent supply. The chip is available with different membrane types, varying in characteristics such as pore size.

Fluidic 653 can be utilized, for instance, in cell culture experiments, where cells, such as epithelial cells, are co-cultured. The chip is also ideal for applications like filtering, size exclusion, or migration studies.

The cross-flow membrane chip Fluidic 653 can be ordered as an open system for self-assembly.

Cross-Flow Membrane Chip Organ-on-Chip and more Fluidic 653

The cross-flow membrane chip Fluidic 653 is a versatile microfluidic tool for organ-on-chip but also filtering experiments.

Material
Surface Treatment
Membrane pore size
€79.50 / unit
€63.50 / unit from 10 units
€42.50 / unit from 100 units
favorite_border favorite
Reference
10001561
Design element
Chamber, Membrane, Barrier
Application
Cell culture, Organ-on-Chip, Sorting, Filtration
Usage Statement
For R&D use only, Single use
Fluidic
653
Material
Topas
Material chip body
Mcs-COC 13
Material chip lid
Mcs-foil 011 (Topas, 140 µm, Tg 78°C)
Color
Transparent
Interface type
Mini luer
Surface treatment
Not treated
Membrane
Mcs-membrane 132 (0.4 µm pores, transparent)
Pieces per unit
1

Description

The cross-flow membrane chip Fluidic 653 possesses two independent chambers that interact through a permeable membrane. Each chamber features one main inlet and outlet, along with two additional (optional) inlets and outlets for additional reagent supply. The chip is available with different membrane types, varying in characteristics such as pore size.

Fluidic 653 can be utilized, for instance, in cell culture experiments, where cells, such as epithelial cells, are co-cultured. The chip is also ideal for applications like filtering, size exclusion, or migration studies.

The cross-flow membrane chip Fluidic 653 can be ordered as an open system for self-assembly.