The spheroid chip Fluidic 1407 facilitates the insertion and separation of pre-cultivated spheroids, as well as the formation and cultivation of spheroidal cell structures, with on-chip imaging capabilities.
Goblet-shaped catcher structures are strategically arranged along a meandering, band-like main channel. Each catcher structure is succeeded by a small passage channel, generating a suction effect during fluidic operation, thereby drawing spheroids into the catcher structures.
This test chip design offers four variations in structure dimensions for both the catchers and passage channels, available in single or double loops, totaling 12 structures on the chip. Each of the twelve units feature a bubble catcher trap on the channel input side.
Please note: For improved spheroid formation and to reduce cell adhesion to the channel surface, a special surface treatment is recommended. For more information, please reach out to inquiries@microfluidic-ChipShop.com