The straight channel chip Fluidic 560 is ideal for many microfluidic experiments where a simple flow cell is required. The chip features four identical channels, enabling the user to carry out multiple experiments using one individual chip. With direct access to the microstructures, experimental preparation steps are no longer a challenge (e.g. spotting, pre-treatment, immunoassays and much more)
Each channel features the following dimensions:
Channel depth: 350+140 µm
Channel width: 2.775 mm
Channel length: 58.5 mm
The back of the chip is covered with a double-sided adhesive (140 µm high). After removing the protective foil from the adhesive, the user can close the channel with a microscope slide or pre-cut foil (not included).
Note: The technical datasheet presents the dimensions of the injection molded chip body only and doesn't account for the depth added by the double-sided adhesive tape.
Watch this video for more information on assembling your open channel chip.
Adhesive Straight Channel Chip H 350+140 µm, W 2775 µm channel Fluidic 560
The adhesive straight channel chip Fluidic 560 is a versatile flow cell for any microfluidic experiment or assay development. The chip features four identical channels.
The straight channel chip Fluidic 560 is ideal for many microfluidic experiments where a simple flow cell is required. The chip features four identical channels, enabling the user to carry out multiple experiments using one individual chip. With direct access to the microstructures, experimental preparation steps are no longer a challenge (e.g. spotting, pre-treatment, immunoassays and much more)
Each channel features the following dimensions:
Channel depth: 350+140 µm
Channel width: 2.775 mm
Channel length: 58.5 mm
The back of the chip is covered with a double-sided adhesive (140 µm high). After removing the protective foil from the adhesive, the user can close the channel with a microscope slide or pre-cut foil (not included).
Note: The technical datasheet presents the dimensions of the injection molded chip body only and doesn't account for the depth added by the double-sided adhesive tape.
Watch this video for more information on assembling your open channel chip.
The straight channel chip Fluidic 560 is ideal for many microfluidic experiments where a simple flow cell is required. The chip features four identical channels, enabling the user to carry out multiple experiments using one individual chip. With direct access to the microstructures, experimental preparation steps are no longer a challenge (e.g. spotting, pre-treatment, immunoassays and much more)
Each channel features the following dimensions:
Channel depth: 350+140 µm
Channel width: 2.775 mm
Channel length: 58.5 mm
The back of the chip is covered with a double-sided adhesive (140 µm high). After removing the protective foil from the adhesive, the user can close the channel with a microscope slide or pre-cut foil (not included).
Note: The technical datasheet presents the dimensions of the injection molded chip body only and doesn't account for the depth added by the double-sided adhesive tape.
Watch this video for more information on assembling your open channel chip.
The adhesive straight channel chip Fluidic 560 is a versatile flow cell for any microfluidic experiment or assay development. The chip features four identical channels.
The adhesive straight channel chip Fluidic 560 is a versatile flow cell for any microfluidic experiment or assay development. The chip features four identical channels.
Adhesive Straight Channel Chip - H 350+140 µm, W 2775 µm channel - Fluidic 560